GF Signet

GF Signet 2724-2726 pH/ORP Electrodes

SKU · 36943 · 2724-2726 · Marca: GF Signet
Disponible
Cotización a solicitud
Sin pago en línea · líneas en BOM RFQ
Descargar datasheet PDF

RFQ solo líneas BOM. Envíe para cotización de ingeniería.

Parámetros clave

Process connection
¾ in NPT or ISO 7/1-R 3/4; mounts in GF fittings ½–4 in
Type
General-purpose DryLoc pH/ORP electrodes (2724 flat pH, 2726 bulb pH, 2725 flat ORP)
Ph Range
0 to 14 pH
Orp Range
±2000 mV
Connector
Patented DryLoc gold-plated connector; mates to 2751 Smart Sensor Electronics
Body
PPS threaded sensor body; UHMW PE reference junction; FKM seals
Descargar datasheet PDF
ParámetroValor
Process connection¾ in NPT or ISO 7/1-R 3/4; mounts in GF fittings ½–4 in
TypeGeneral-purpose DryLoc pH/ORP electrodes (2724 flat pH, 2726 bulb pH, 2725 flat ORP)
Ph Range0 to 14 pH
Orp Range±2000 mV
ConnectorPatented DryLoc gold-plated connector; mates to 2751 Smart Sensor Electronics
BodyPPS threaded sensor body; UHMW PE reference junction; FKM seals
TemperatureBulb 0…85 °C; flat −10…85 °C
PressureUp to 6.8 bar @ 0–65 °C (100 psi @ 32–150 °F) typical; derate at higher T
OptionsHF-resistant glass (trace HF ≤2%); low-conductivity LC 20–100 µS/cm
Temp SensorPt1000 or 3K Balco versions for SmartPro / 9900 / 9950
ApplicationIndustrial/municipal water treatment, aquaculture, agriculture, water parks
DocumentDatasheet Type 2724-2726 Rev O + DryLoc series manual