Image unavailable
Image unavailable
Fluke
Fluke 773 Milliamp Process Clamp Meter
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Measuring range
mA clamp 0–20.99 mA / 21.0–100.0 mA; in-circuit mA 0–24.00 mA; V DC measure 0–30.00 V; V DC source 0–10.00 V; loop power 24 V DC
Accuracy
mA clamp 0.2% + 5 counts (0–20.99 mA), 1% + 5 counts (21–100 mA); in-circuit/source/simulate mA 0.2% + 2 counts; V DC 0.2% + 2 counts
Output
mA source/simulate 0–24 mA; scaled mA output; V DC source 0–10 V; 24 V loop power; 250 Ω HART resistor
Supply
4× AA alkaline IEC LR6; ~12 h @ 12 mA source into 500 Ω
Electrical connection
Detachable remote jaw (max conductor Ø 4.5 mm) via extension cable; test jacks for series mA / V
Protection
IP40
| Параметр | Значение |
|---|---|
| Measuring range | mA clamp 0–20.99 mA / 21.0–100.0 mA; in-circuit mA 0–24.00 mA; V DC measure 0–30.00 V; V DC source 0–10.00 V; loop power 24 V DC |
| Accuracy | mA clamp 0.2% + 5 counts (0–20.99 mA), 1% + 5 counts (21–100 mA); in-circuit/source/simulate mA 0.2% + 2 counts; V DC 0.2% + 2 counts |
| Output | mA source/simulate 0–24 mA; scaled mA output; V DC source 0–10 V; 24 V loop power; 250 Ω HART resistor |
| Supply | 4× AA alkaline IEC LR6; ~12 h @ 12 mA source into 500 Ω |
| Electrical connection | Detachable remote jaw (max conductor Ø 4.5 mm) via extension cable; test jacks for series mA / V |
| Protection | IP40 |
| Ambient temperature | Operating −10…+50 °C; storage −25…+60 °C; altitude 0–2000 m |
| Display | Backlit LCD with % span, hold, spotlight LED |
| Approvals | CE; EN61326-1 EMC |
| Mounting | Handheld portable process clamp meter |
| Notes | Size ~41.3×76×248 mm. Simultaneous mA in/out (773). OEM Technical Data 3442293 + Instruction Sheet. |
| Weight | 415 g (approx.) |