Image unavailable
Image unavailable
Cast Aluminum Solutions (CAS)
CAS CAST-X 500 Circulation Heater
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Type
Compact cast-aluminum circulation heater (CAST-X 500)
Power
Up to 1500 W; 110–240 V; max line current 12.5 A
Tubing
0.250 in OD × 0.035 in wall 316L SS (Inconel optional); 84 in process tube length
Max Pressure
5100 psi (351 bar)
Enclosures
None / NEMA 1 / NEMA 4 / NEMA 7
Max Working Temperature
No enclosure / NEMA 7: 392 °F (200 °C); NEMA 1/4: 250 °F (121 °C)
| Параметр | Значение |
|---|---|
| Type | Compact cast-aluminum circulation heater (CAST-X 500) |
| Power | Up to 1500 W; 110–240 V; max line current 12.5 A |
| Tubing | 0.250 in OD × 0.035 in wall 316L SS (Inconel optional); 84 in process tube length |
| Max Pressure | 5100 psi (351 bar) |
| Enclosures | None / NEMA 1 / NEMA 4 / NEMA 7 |
| Max Working Temperature | No enclosure / NEMA 7: 392 °F (200 °C); NEMA 1/4: 250 °F (121 °C) |
| Sensors | J/K thermocouples or RTDs; snap-action high-limit on no-enclosure versions |
| Media Path | Media isolated in seamless SS tubes — no contact with heating elements |
| Document | CAS CAST-X 500 technical brochure / product page specs |