Ключевые параметры
Accuracy
±0.2% of set span; optional Platinum ±0.1%
Supply
10.5…35 V DC (Ex: 10.5…30 V DC)
Process connection
Suspension clamp; cable mounting screw G1½ / NPT 1½
Wetted parts
316L / ceramic / PPS-polyolefin (version-dependent); cable PE/PUR/FEP
Approvals
ATEX/FM/CSA/IECEx; marine GL/ABS/BV/DNV; drinking water NSF/KTW/ACS
Measuring Principle
Hydrostatic pressure; capacitive ceramic cell
| Параметр | Значение |
|---|---|
| Accuracy | ±0.2% of set span; optional Platinum ±0.1% |
| Supply | 10.5…35 V DC (Ex: 10.5…30 V DC) |
| Process connection | Suspension clamp; cable mounting screw G1½ / NPT 1½ |
| Wetted parts | 316L / ceramic / PPS-polyolefin (version-dependent); cable PE/PUR/FEP |
| Approvals | ATEX/FM/CSA/IECEx; marine GL/ABS/BV/DNV; drinking water NSF/KTW/ACS |
| Measuring Principle | Hydrostatic pressure; capacitive ceramic cell |
| Pressure Range | 100 mbar…20 bar (1.5…300 psi); max 200 m H2O |
| Process Temperature | -10…+70 °C (29 mm saltwater: 0…+50 °C) |
| Probe Diameters | 22 mm (fresh water); 42 mm (wastewater); 29 mm (saltwater) |