Ключевые параметры

Measuring range
Hydrostatic level; factory/customer measuring ranges typically 200 mbar–2 bar (up to ~20 m H2O class)
Accuracy
Reference accuracy ≤ ±0.35% for sensor measuring range ≥ 400 mbar (IEC 60770)
Output
4–20 mA analog, 2-wire (signal range 2–22 mA)
Supply
8–28 V DC
Protection
IP68 class submersible probe (degree of protection per TI)
Ambient temperature
Per TI ambient/storage tables; medium temperature limits in process chapter
Скачать datasheet PDF
ПараметрЗначение
Measuring rangeHydrostatic level; factory/customer measuring ranges typically 200 mbar–2 bar (up to ~20 m H2O class)
AccuracyReference accuracy ≤ ±0.35% for sensor measuring range ≥ 400 mbar (IEC 60770)
Output4–20 mA analog, 2-wire (signal range 2–22 mA)
Supply8–28 V DC
ProtectionIP68 class submersible probe (degree of protection per TI)
Ambient temperaturePer TI ambient/storage tables; medium temperature limits in process chapter
ApprovalsDrinking water (per TI); PED
MountingFreely suspended cable probe; suitable for narrow 1 in pipes / groundwater wells
Sensor typeMetal measuring cell with filling oil / Wheatstone bridge (relative or absolute)
NotesCatalog SKU title Waterpilot FMX12 has no current endress.com match; OEM mapping to Waterpilot FMX11 (TI01524P) analogous to prior FMX23→FMX21 harvests. product_name retains catalog FMX12; model=Waterpilot FMX11.
CableOrderable PE extension cables (e.g. 6 m / 10 m) shorten-able; shielded twisted pair recommended
Power Consumption≤ 0.62 W at 28 V DC
ApplicationFreshwater / groundwater wells, rivers, lakes, storage tanks