Ключевые параметры

Measuring range
Point level; sensor length up to 6 m (20 ft) depending on installation/extension ordered
Accuracy
Millimetre-class switching point (product-independent); hysteresis/switching delay per electronics
Output
Electronic inserts: 2-wire AC (FEL61); 3-wire DC PNP (FEL62); universal AC/DC relay (FEL64); DC relay (FEL64DC); PFM (FEL67); 2-wire NAMUR (FEL68); HART/PROFINET-APL variants in related TI
Supply
Depends on insert: e.g. FEL61 19–253 VAC; FEL62 PLC PNP (SELV/CLASS 2); FEL64 19–253 VAC / 19–55 VDC; FEL64DC 9–20 VDC
Process connection
Threads, flanges, hygienic (Tri-Clamp) per order
Wetted parts
316L, Alloy (sensor); process adapters per TI
Скачать datasheet PDF
ПараметрЗначение
Measuring rangePoint level; sensor length up to 6 m (20 ft) depending on installation/extension ordered
AccuracyMillimetre-class switching point (product-independent); hysteresis/switching delay per electronics
OutputElectronic inserts: 2-wire AC (FEL61); 3-wire DC PNP (FEL62); universal AC/DC relay (FEL64); DC relay (FEL64DC); PFM (FEL67); 2-wire NAMUR (FEL68); HART/PROFINET-APL variants in related TI
SupplyDepends on insert: e.g. FEL61 19–253 VAC; FEL62 PLC PNP (SELV/CLASS 2); FEL64 19–253 VAC / 19–55 VDC; FEL64DC 9–20 VDC
Process connectionThreads, flanges, hygienic (Tri-Clamp) per order
Wetted parts316L, Alloy (sensor); process adapters per TI
HousingField housing with M20 / ½ NPT / M12 entries
ProtectionIP66/68 NEMA Type 4X/6P (cable entries); M12 plugged IP66/67; IP68 test 1.83 m H2O 24 h
Media temperature−50 to +150 °C (−58 to +302 °F)
Ambient temperatureAmbient range per TI environment section (electronics options to −60 °C LT)
DisplayOptional LED module VU120; Bluetooth module VU121
CommunicationBluetooth (Heartbeat/SmartBlue); optional HART / Ethernet-APL variants
ApprovalsSIL2; SIL3; ATEX; IECEx; WHG; CE
NotesSpecs from E+H TI01403F EN 07.25-00 (2025-10-13).
Process PressureVacuum…100 bar (1450 psi)
Min Density0.5 g/cm³ (0.4 g/cm³ optional); density selection switch >0.7 g/cm³ typical
ViscosityUp to 10000 mPa·s