Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Liquiphant FTL41 Level Switch
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Measuring range
Point level with optional extension tube; density 0.5 g/cm³ (0.4 g/cm³ optional)
Accuracy
Vibronic frequency switching; no media calibration required
Output
Electronic inserts incl. 3-wire DC-PNP (FEL42) and other FEL variants per TI01402
Supply
Per electronic insert (see TI01402 electrical tables)
Process connection
Threads, flanges, hygienic Tri-Clamp options
Wetted parts
Sensor 316L
| Параметр | Значение |
|---|---|
| Measuring range | Point level with optional extension tube; density 0.5 g/cm³ (0.4 g/cm³ optional) |
| Accuracy | Vibronic frequency switching; no media calibration required |
| Output | Electronic inserts incl. 3-wire DC-PNP (FEL42) and other FEL variants per TI01402 |
| Supply | Per electronic insert (see TI01402 electrical tables) |
| Process connection | Threads, flanges, hygienic Tri-Clamp options |
| Wetted parts | Sensor 316L |
| Housing | Per order code (see TI01402) |
| Protection | IP66/67 NEMA Type 4X with correctly fitted M12 cable (see TI notices) |
| Media temperature | −40 to +150 °C (−40 to +302 °F) |
| Ambient temperature | See TI01402 ambient/process derating charts |
| Approvals | International Ex certificates (order-dependent); WHG; CE |
| Notes | Specs from Endress+Hauser TI01402F/00/EN/07.26-00 (2026-09-11) + product page. |
| Process Pressure | Vacuum … 40 bar (Vacuum … 580 psi) |
| Min Density | 0.5 g/cm³ (0.4 g/cm³ optional) |
| Viscosity | Up to 10000 mPa·s |