Image unavailable
Image unavailable
Badger Meter
Badger Meter ModMAG M2000 Electromagnetic Flow Meter
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Measuring range
Flow 0.03–12 m/s (0.10–39.4 ft/s); meter sizes 6–1981 mm (¼–78 in)
Accuracy
±0.20% of rate ±1 mm/s with appropriate straight run; ±1% with zero straight run (limited space)
Accuracy % FS
0.2
Output
Scaled pulse, analog 4–20 mA, digital status; protocol daughterboards
Supply
10–36 V DC or 85–265 V AC
Process connection
Flanged / wafer detector styles by size (see PDS MAG-DS-01047)
| Параметр | Значение |
|---|---|
| Measuring range | Flow 0.03–12 m/s (0.10–39.4 ft/s); meter sizes 6–1981 mm (¼–78 in) |
| Accuracy | ±0.20% of rate ±1 mm/s with appropriate straight run; ±1% with zero straight run (limited space) |
| Accuracy % FS | 0.2 |
| Output | Scaled pulse, analog 4–20 mA, digital status; protocol daughterboards |
| Supply | 10–36 V DC or 85–265 V AC |
| Process connection | Flanged / wafer detector styles by size (see PDS MAG-DS-01047) |
| Electrical connection | Amplifier terminal compartments; remote/amplifier options |
| Wetted parts | Liner and electrode material options for media compatibility (PTFE and others per PDS) |
| Housing | Detector/amplifier housings per PDS |
| Protection | Per amplifier/detector enclosure rating in PDS |
| Media temperature | Up to 150 °C (302 °F) depending on liner/electrode selection |
| Ambient temperature | Per amplifier ambient limits in PDS |
| Pressure type | other |
| Display | Amplifier local display/keypad |
| Communication | RS232 Modbus RTU standard; options Modbus RTU/HART/Profibus DP/BACnet MS/TP/BACnet/IP/Modbus TCP/IP/EtherNet/IP |
| Approvals | NSF (selected); CSA ordinary location; OIML (selected); WRAS/KTW hygiene options |
| Mounting | Inline full-bore magmeter; compact or remote amplifier |
| Notes | OEM Badger Meter MAG-DS-01047-EN-33 via widen CDN. Minimum electrical conductivity liquids. |
| Overpressure Limit | Flange/pressure rating by meter size and flange class |