Image unavailable
Image unavailable
Alicat Scientific
Alicat Scientific L / LC Series Liquid Flow Meters and Controllers
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Accuracy
±2.0% of full scale volumetric (water media at calibration conditions)
Wetted parts
316L/303 stainless with FKM (EPDM/FFKM optional); LCS/LCRS use FFKM
Display
Monochrome LCD or color TFT; volumetric flow, temperature, setpoint (LC), pressure
Flow Range
0.5 CCM–10 LPM full scale (meter and controller families)
Repeatability
±0.2% of full scale
Control Range
LC steady-state control 0.01–100% of full scale
| Параметр | Значение |
|---|---|
| Accuracy | ±2.0% of full scale volumetric (water media at calibration conditions) |
| Wetted parts | 316L/303 stainless with FKM (EPDM/FFKM optional); LCS/LCRS use FFKM |
| Display | Monochrome LCD or color TFT; volumetric flow, temperature, setpoint (LC), pressure |
| Flow Range | 0.5 CCM–10 LPM full scale (meter and controller families) |
| Repeatability | ±0.2% of full scale |
| Control Range | LC steady-state control 0.01–100% of full scale |
| Operating Pressure | Meter operating ~100 PSIG sensor FS; damage possible above 200 PSIG common mode / 75 PSID |
| Operating Temperature | −10–60 °C (medium must remain liquid) |
| Valve Function | LC: normally closed |
| Media | Default ultrapure/RO/DI water; alternate fluids ~0.1–3.0 cP with custom calibration |
| Ingress Protection | IP40 |
| Communications | RS-232/Modbus RTU default; optional industrial protocols |
| Analog Io | 4–20 mA, 0–5 Vdc, 1–5 Vdc, 0–10 Vdc |
| Power Requirements | LC/LCS 12–30 Vdc 250 mA; LCR/LCRS 24 Vdc 600 mA |
| Control Response | LC as fast as 30 ms T63 (user-adjustable) |