Ключевые параметры

Measuring range
0–10% O2 configurable to 0–50%
Accuracy
±0.75% of reading or ±0.05% O2 (whichever greater)
Ambient temperature
−40 to 70 °C (−40 to 158 °F)
Approvals
6888C: ATEX/IECEx Ex d and CSA Class I Div 1/Zone 1
Type
In-situ zirconia flue-gas oxygen analyzer/transmitter (Rosemount 6888A/C + optional Xi)
Sensing
Robust zirconia cell with catalytic platinized beads (sulfur poisoning resistance)
Скачать datasheet PDF
ПараметрЗначение
Measuring range0–10% O2 configurable to 0–50%
Accuracy±0.75% of reading or ±0.05% O2 (whichever greater)
Ambient temperature−40 to 70 °C (−40 to 158 °F)
Approvals6888C: ATEX/IECEx Ex d and CSA Class I Div 1/Zone 1
TypeIn-situ zirconia flue-gas oxygen analyzer/transmitter (Rosemount 6888A/C + optional Xi)
SensingRobust zirconia cell with catalytic platinized beads (sulfur poisoning resistance)
Communications4–20 mA HART 5; FOUNDATION Fieldbus
Process TemperatureUp to 705 °C (1300 °F); higher with optional bypass/jacket (~1050 °C)
Probe LengthsOptions from 18 in (0.46 m) to 12 ft (3.66 m)
DiagnosticsCalibration recommended; plugged diffuser/filter; low-O2 / reducing conditions
DocumentPDS 00813-0100-4890 Rev AC + RM 00809-0100-4890