Ключевые параметры
Measuring range
0.75 to 600 mH2O gauge; absolute from 3.5 mH2O (PDCR/PTX 1800)
Accuracy
±0.10% FS BSL standard (combined NL/H/R)
Output
PDCR1800 mV output; PTX1800 4–20 mA two-wire transmitter
Approvals
CE
Body Material
Fully welded titanium, 17.5 mm diameter slimline body
Cable
Polyurethane or Hytrel 6108; Kevlar strain cord; IP68 to 700 mH2O
| Параметр | Значение |
|---|---|
| Measuring range | 0.75 to 600 mH2O gauge; absolute from 3.5 mH2O (PDCR/PTX 1800) |
| Accuracy | ±0.10% FS BSL standard (combined NL/H/R) |
| Output | PDCR1800 mV output; PTX1800 4–20 mA two-wire transmitter |
| Approvals | CE |
| Body Material | Fully welded titanium, 17.5 mm diameter slimline body |
| Cable | Polyurethane or Hytrel 6108; Kevlar strain cord; IP68 to 700 mH2O |
| Overpressure | Up to 8× FS (≤1.5 mH2O); 6× or 4× higher ranges (1400 mH2O max) |
| Excitation | PDCR1800: 10 V at 5 mA nominal |
| Media Compatibility | Fluids compatible with titanium body, acetyl nose cone, PU/Hytrel cable |
| Form Factor | Fully submersible depth/level pressure sensor for potable water, wastewater, tanks, seawater |
| Installation | Datum-marked cable; quick-release clamp, sink weights, STE termination accessories |
| Special Features | Micromachined silicon isolated in titanium module; long-term immersion IP68 |