Image unavailable
Image unavailable
Endress+Hauser
Endress+Hauser Thermophant T TTR35 Temperature Switch
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Measuring range
−50 to 150 °C (−58 to 302 °F); −50 to 200 °C with extension neck
Output
1× PNP; 2× PNP; or PNP + active 4–20 mA
Supply
12 to 30 VDC
Process connection
Hygienic: conical metal-metal G½"; Clamp 1"–2" DIN 32676; Varivent F/N; DIN 11851; APV Inline
Wetted parts
Process connection AISI 316L
Ambient temperature
−40 to 85 °C
| Параметр | Значение |
|---|---|
| Measuring range | −50 to 150 °C (−58 to 302 °F); −50 to 200 °C with extension neck |
| Output | 1× PNP; 2× PNP; or PNP + active 4–20 mA |
| Supply | 12 to 30 VDC |
| Process connection | Hygienic: conical metal-metal G½"; Clamp 1"–2" DIN 32676; Varivent F/N; DIN 11851; APV Inline |
| Wetted parts | Process connection AISI 316L |
| Ambient temperature | −40 to 85 °C |
| Display | Local digital display and LEDs |
| Sensor | Pt100 RTD, Class A per IEC 60751; FDA-compliant hygienic design |
| Accuracy Total Error | ≤0.5 K (−50…75 °C); ≤0.75 K (75…200 °C) |
| Degree Of Protection | IP65/IP66; IP69K optional with locking connector |
| Sensor Response Time | t50 < 1.0 s; t90 < 2.0 s in flowing water per IEC 60751 |
| Long Term Drift | ≤0.1 K/a |
| Hygiene Standard | 3-A mark; materials in contact with food/product documented in TI |
| Min Measuring Span | 20 K |