Image unavailable
Image unavailable
Jewell Instruments
Jewell Instruments C801 Tuff Tilt 420 Analog Tiltmeter
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF
RFQ только BOM. Отправьте для инженерного КП.
Ключевые параметры
Output
4–20 mA two-wire current loop per axis
Supply
(0.02 A × R + 10 VDC) < Vs < 29 VDC; input current 25 mA
Angular Range
±0.5° (high-gain), ±3° (standard), or ±50° (wide-angle); custom ranges on request
Resolution
0.0001° / 0.0006° / 0.01° by range
Nonrepeatability
0.0002° / 0.001° / 0.02° max by range
Nonlinearity
1% / 2% / 0.5% FRO max by range
| Параметр | Значение |
|---|---|
| Output | 4–20 mA two-wire current loop per axis |
| Supply | (0.02 A × R + 10 VDC) < Vs < 29 VDC; input current 25 mA |
| Angular Range | ±0.5° (high-gain), ±3° (standard), or ±50° (wide-angle); custom ranges on request |
| Resolution | 0.0001° / 0.0006° / 0.01° by range |
| Nonrepeatability | 0.0002° / 0.001° / 0.02° max by range |
| Nonlinearity | 1% / 2% / 0.5% FRO max by range |
| Scale Factor | 0.0625°/mA / 0.375°/mA / 6.25°/mA (single-ended) by range |
| Axes | 1 (uniaxial) or 2 (biaxial) |
| Temperature Channel | 10 kΩ thermistor; −50 to +150 °C measurement span |
| Time Constant | 0.15 s |
| Operating Temperature | −40 to +85 °C |
| Enclosure | Diecast painted aluminum; IP65; ~120 × 80 × 60 mm; 0.5–0.6 kg |
| Cable | 3 m (10 ft) multi-conductor + overall shield, PVC jacket |