Jewell Instruments

Jewell Instruments Model A820 Shallow Water Analog Tiltmeter

SKU · 44466 · Model A820 Series Tiltmeter · Бренд: Jewell Instruments
В наличии
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF

RFQ только BOM. Отправьте для инженерного КП.

Ключевые параметры

Angular Ranges
±0.5° (high-gain), ±3° (standard), ±50° (wide-angle)
Resolution
<0.0001° / 0.0006° / 0.01° by range
Nonrepeatability
<0.0002° / 0.001° / 0.02° by range
Nonlinearity
1% FRO (±0.5°); 2% FRO (±3°/±50°)
Scale Factor
0.1°/V; 0.6°/V; 10°/V by range
Axes
1 or 2 (longitudinal / transverse / biaxial ordering)
Скачать datasheet PDF
ПараметрЗначение
Angular Ranges±0.5° (high-gain), ±3° (standard), ±50° (wide-angle)
Resolution<0.0001° / 0.0006° / 0.01° by range
Nonrepeatability<0.0002° / 0.001° / 0.02° by range
Nonlinearity1% FRO (±0.5°); 2% FRO (±3°/±50°)
Scale Factor0.1°/V; 0.6°/V; 10°/V by range
Axes1 or 2 (longitudinal / transverse / biaxial ordering)
Power8–18 VDC @ 8 mA, 250 mV ripple max, reverse-polarity protected
Operating Temperature−4 to +60°C (storage −30 to +100°C)
Submersion Rating200 m (656.2 ft) waterproof
Materials Weight316 stainless steel; 1.6 kg
Dimensions92.1 × 112.4 × 61 mm (catalog)
Temperature Output0.1°C/mV typical (0°C = 0 mV)
Output Impedance270 Ω nominal