Pulsar Measurement

Pulsar Measurement Greyline OCF 6.1 Open Channel Flow Meter

SKU · 47770 · Greyline OCF 6.1 · Бренд: Pulsar Measurement
В наличии
Цена по запросу
Без онлайн-оплаты · строки в RFQ BOM
Скачать datasheet PDF

RFQ только BOM. Отправьте для инженерного КП.

Ключевые параметры

Accuracy
±0.25% of range or 2 mm (0.08 in), whichever greater
Approvals
CE, cCSAus; sensor non-incendive Class I Div 2; optional I.S. barriers for Div 1
Type
Non-contacting ultrasonic open-channel flow and tank level meter (Greyline OCF 6.1)
Sensor Range
PZ15: 4.6 m (15 ft); PZ32T: 9.8 m (32 ft)
Deadband
Programmable; minimum 203.2 mm (8 in)
Outputs
Isolated 4–20 mA / 0–5 V; 2× form-C relays 5 A SPDT
Скачать datasheet PDF
ПараметрЗначение
Accuracy±0.25% of range or 2 mm (0.08 in), whichever greater
ApprovalsCE, cCSAus; sensor non-incendive Class I Div 2; optional I.S. barriers for Div 1
TypeNon-contacting ultrasonic open-channel flow and tank level meter (Greyline OCF 6.1)
Sensor RangePZ15: 4.6 m (15 ft); PZ32T: 9.8 m (32 ft)
DeadbandProgrammable; minimum 203.2 mm (8 in)
OutputsIsolated 4–20 mA / 0–5 V; 2× form-C relays 5 A SPDT
LoggingBuilt-in 26-million-point data logger with USB output
CommunicationsOptional Modbus RTU via RS-485
Electronics Temp−20 °C to 60 °C (−5 °F to 140 °F)
Power100–240 V AC 50/60 Hz; optional 9–32 V DC